The following are some of the ways in which we can assist building owners, operators, and facility staff:
Performing balance and troubleshooting on air and hydronic systems
Investigation in the field and labeling of devices
What is HVAC assessmentLeak testing and investigations on the pressurized and ducted systems
The verification of the temperature control system
The year 2003 marked the beginning of NorthWest Engineering Service Inc.'s work on FLS systems. Because of our extensive experience in Commissioning (Cx) and Testing, Adjusting, and Balancing (TAB), we are in a truly unique position to carry out audit surveys of HVAC systems, identify and functionally test all Fire Smoke Dampers, and offer documentation to meet the standards of the AHJ.
Analyses of the quality of the air inside
TESTING OF THE FIRE AND SMOKE DAMPER
Testing for sound and vibration in HVAC systems
Building heating, ventilation, and air conditioning system drawings that document the positions of fire smoke dampers
Facilities for both transition and rehabilitation purposes
Buildings used for businesses
Testing, Changing, and Balancing is an acronym that stands for Testing, Adjusting, and Balancing, and it refers to the process of monitoring and adjusting the flow of air and water to satisfy design criteria. The TAB process involves employing test instruments, sensors, and monitors to check suitable temperatures, airflow, and other parameters inside the HVAC system. This is done in order to complete the TAB process. In order to ensure that heating, ventilation, and air conditioning (HVAC) systems are optimized for occupant comfort, energy efficiency, indoor air quality, and manufacturing processes, testing, adjusting, and balancing is a crucial step for complex air and hydronic systems found within buildings and throughout campuses.
Authorities Having Jurisdiction (AHJ) at the federal, state, and municipal levels have expanded their FSD testing code enforcement efforts beyond the healthcare industry to include the following:
Testing for FSD in the states of Oregon, Idaho, and Washington
Fixing problems with the exhaust system
Components of the photo log FSD and damper functions have been sorted.
facilities for assisted living as well as acute care
Establishments devoted to education
Local authorities, in addition to national organizations such as the National Fire Protection Association (NFPA) and the International Code Council (ICC), are the ones responsible for defining the standards and norms that apply to FLS systems. The owners of the facilities are the ones who are responsible for testing their systems at the right intervals and ensuring that they have the proper paperwork to demonstrate that their systems are functional.
Excel file for testing dampers that lists access requirements